| Freebird Gas Storage L.L.C. | Original Sheet No. 125 : Effective | |
| FERC Gas Tariff | ||
| Freebird Gas Storage L.L.C. | ||
Replacement Shipper shall revise its nominations within the applicable nomination cycle in order to implement the recall. Each affected Replacement Shipper will be solely responsible for adjusting its supply and transportation arrangements, which may be necessary as a result of such recall. Replacement Shippers involved in re-release transactions may receive notice slightly after the first Replacement Shipper receives notice. The recalling Releasing Shipper may nominate the recalled capacity consistent with the applicable nomination cycle, as defined in Section 8.2 of these General Terms and Conditions. (f) Partial Day Recall Quantity. The daily contractual entitlement that can be recalled by a Releasing Shipper for a partial Day recall is a quantity equal to the lesser of: (a) The quantity specified in the Releasing Shipper’s notice to recall capacity; or (b) The difference between the quantity released by the Releasing Shipper and the Elapsed Prorata Capacity Quantity. In the recall notification provided to Freebird by the Releasing Shipper, the quantity to be recalled shall be expressed in terms of the adjusted total released capacity entitlements based upon the Elapsed Prorata Capacity. In the event of an intraday capacity recall, Freebird shall determine the allocation of capacity between the Releasing Shipper and the Replacement Shipper(s) based upon the Elapsed Prorata Capacity (EPC). Variations to the use of the EPC may be necessary to reflect the nature of Freebird’s tariff services, and/or operational characteristics. Freebird shall not be obligated to deliver in excess of the total daily contract quantity of the release as a result of NAESB WGQ Standard No. 5.3.55, as set forth in this Section 4.13(f). The amount of capacity allocated to the Replacement Shipper(s) should equal the original released capacity less the recalled capacity that is adjusted based upon the EPC or other tariff specific variations of the EPC in accordance with NAESB WGQ Standard No. 5.3.56. The amount of capacity allocated to the Replacement Shipper(s) shall equal the original released quantity less the recalled capacity. This allocated daily contractual quantity shall be used for purposes of nominations, billing, and if applicable, for overrun calculations. (g) Reput Provisions. Freebird shall support the function of reputting by the Releasing Shipper. The Releasing Shipper may reput previously recalled capacity to the Replacement Shipper pursuant to the reput rights and methods identified in the Releasing Shipper’s notice to release capacity, as required by Section 4.1(g). When capacity is recalled, such capacity may not be reput for the same Day. The deadline for the Releasing Shipper to notify Freebird of a reput of capacity is 8:00 A.M. CCT to allow the Replacement Shipper to submit timely nominations for Gas to flow on the next Gas Day. (h) Following the awarding of capacity to a Replacement Shipper in accordance with the procedures provided in this Section, the Releasing Shipper’s rights and Freebird’s obligations under the Releasing Shipper’s Service Agreement shall be modified and subject to the capacity rights released and assigned to the Replacement Shipper for the term of such release. Effecting a release pursuant to the provisions of this Section shall constitute Releasing Shipper’s consent and agreement to such amendment or modification of its existing Service Agreement. (i) The quantities of MSQ, MDIQ and MDWQ must be in the same proportions reltive to each other as is set forth in the Releasing Shipper’s original FSS Service Agreement. The offer to release by a Shipper under Rate Schedule FSS must specify the quantities of MSQ, MDIQ, MDWQ or rights offered, and actually available on the effective date of the assignment, and the exercise of such rights, in
| Issued by: Patrick DeVille Vice President, Marketing | ||
| Issue date: | Effective date: 10/01/08 | |