| Bluelake Storage Company |
|
Original Sheet No. 135 : Effective |
| FERC Gas Tariff |
|
|
| Bluelake Storage Company |
GENERAL TERMS AND CONDITIONS
(Continued)
4.7 Reduction in Maximum Storage Quantity. In the event that
Customer nominates or utilizes less than 50% of its Maximum
Storage Quantity under Rate Schedule IS for a period of one
(1) year, Seller may reduce Customers Maximum Storage
Quantity to 125% of the average utilization during such year,
which new Maximum Storage Quantity, as applicable, shall be
effective on the first Day of the Month following the Month in
which Seller gives Customer notice of such reduction.
5. PRESSURE AT POINT OF INJECTION/WITHDRAWAL
5.1 Pressure at Point of Injection/Withdrawal. Unless otherwise
agreed to by the parties as set forth in the Service
Agreement, Customer shall cause the Gas to be delivered at the
Point of Injection/Withdrawal at a pressure sufficient to
allow the Gas to enter Sellers system at the varying
pressures that may exist in such system from time to time;
provided, however, that such pressure of the Gas delivered or
caused to be delivered by Customer shall not exceed the
Maximum Allowable Operating Pressure ("MAOP") which Seller
specifies for the Point of Injection/Withdrawal. In the event
the MAOP of Sellers system, at the Point of
Injection/Withdrawal hereunder, is from time to time increased
or decreased, then the MAOP of the Gas delivered or caused to
be delivered by Customer to Seller at the Point of
Injection/Withdrawal shall be correspondingly increased or
decreased upon notification by Seller to Customer.
Unless otherwise agreed to by the parties as set forth in the
Service Agreement, Seller shall Tender the Gas to or for the
account of Customer at the Point of Injection/Withdrawal
hereunder at Sellers prevailing line pressure as such may
vary from time to time.
6. MEASUREMENT AND MEASUREMENT EQUIPMENT
6.1(a) The volume of Gas delivered to Seller hereunder or
redelivered to or for the account of Customer hereunder
shall be measured by:
(1) An orifice meter, designed, installed maintained and
operated as recommended in the latest issue of American
National Standard ANSI/API 2530 (American Gas Association
Gas Measurement Report No. 3), entitled "Orifice Metering
| Issued by: M. J. Mujadin, Chairman |
| Issue date: 07/30/93 |
|
Effective date: 08/01/93 |